When Transport Requires More Than Just a Simple Shock Verification
A shock during loading or a critical tilt during a heavy-haul transport can have significant consequences for high-value industrial equipment. However, when assessing such an event, it is often not enough to simply know that a certain threshold value was exceeded.
What is far more important is:
- How strong was the impact?
- How long did it last?
- From which direction did it come?
- When did the event occur?
- How did the impact evolve over time?
The Monilog® ShockDisplay curve 2 was developed precisely to meet these requirements.
This rugged shock recorder captures shock and tilt events during transport, storage, or operation and documents them for later detailed analysis. It is particularly commonly used for monitoring the transport of transformers and other high-value energy equipment.
What is the ShockDisplay curve 2?
The ShockDisplay curve 2 is a transport data logger designed to record mechanical stresses.
It focuses on two risk factors:
- Shock
- Tilt
The device stores the 500 largest mechanical shock events and records them in three dimensions. In addition, tilt events and long-term tilt trends can be documented.
The key difference from simpler data loggers lies in the detailed recording: A shock is not merely stored as a single maximum value. The ShockDisplay curve 2 also documents the corresponding signal curve.
This produces a shock curve that allows for a much more precise analysis of an event.
Not only detect shock events, but also analyze them
Individual detection thresholds can be set prior to transport. If a mechanical load exceeds this defined threshold, the event is automatically recorded. The ShockDisplay curve 2 records the following information, among other things:
- Intensity of the shock
- Direction of the shock
- Time of occurrence
- Duration of the shock
- Minimum and maximum load values
- Signal waveform of the event
Measurements are taken along three spatial axes. This makes it possible to determine the direction from which a force acted on the cargo.
This is particularly important when it is necessary to determine what actually happened after transport. Based on the shock curve and its direction, it is possible, for example, to determine whether the cargo itself was jolted or whether an external force acted on the system.
Why Tilt Can Be Just as Important as Impact
It’s not just a hard impact that can damage cargo. With certain types of equipment, even excessive tilt poses a significant risk.
That’s why the ShockDisplay curve 2 also monitors the position of the cargo.
Tilt angles of up to ±90 degrees can be recorded. In addition to individual tilt events, continuous tilt values can also be documented over longer transport sections. This is particularly important, for example, when transporting transformers.
Practical example: Transport monitoring of a transformer
Large transformers can weigh several tens or even several hundred metric tons. Inside are sensitive components whose position must remain as unchanged as possible during transport.
The magnetic core consists, among other things, of layers of electrical steel sheets stacked on top of one another. Severe shock or tilt loads can cause these sheets to shift.
The windings and their insulation materials can also be compromised by mechanical stress. If components shift or insulation materials are damaged, this can later affect the transformer’s functionality.
The ShockDisplay curve 2 is therefore attached directly to the cargo and accompanies the transformer along the entire transport route.
This creates a traceable data set documenting mechanical impacts during:
- Loading
- Road transport
- Rail transport
- Maritime transport
- Transshipment
- Temporary storage
- Delivery
The interview makes it clear that the ShockDisplay curve, together with the EnDaL smart, is used particularly frequently for monitoring transformers.
View Information Directly on the Device
A key difference within the Monilog® product portfolio is already evident in the name: Display.
The ShockDisplay curve 2 features a backlit LCD display and four function keys. Information such as shock events, shock duration, minimum and maximum values, and alarm statuses can be viewed directly on the device. The date, time, and other status information are also available.
This means that a PC does not necessarily have to be connected immediately for an initial assessment.
The device can also be configured using the control buttons. This offers a practical advantage, especially for varying transport tasks: settings can be checked or adjusted on-site.
Custom Thresholds for Different Cargo Types
Not all cargo can withstand the same levels of stress.
A transformer has different mechanical thresholds than a machine or a generator. That is why the ShockDisplay curve 2 can be adapted to the specific transport task.
Among other things, the following can be configured:
- Detection thresholds for different impact directions
- Minimum impact duration
- Alarm limits for impact loads
- Detection thresholds for tilt events
This means that a single general standard value does not determine which event is relevant. Monitoring can be tailored to the specific risk profile of the cargo.
From the Display to Detailed Analysis
For a more comprehensive analysis, the recorded data can be transferred to a PC via USB.
The accompanying software allows for graphical and tabular displays of the measured values, as well as further analysis of the recorded signal curves.
This makes it possible to examine individual shock events more closely and compare them with the actual transport process. Timing plays a crucial role in this process.
For example, if a critical shock is recorded during a specific transshipment operation, the event can be assigned to that transport segment and subsequently investigated in detail.
Designed for use in demanding conditions
Transport data loggers are often installed directly on large industrial equipment and must be sufficiently rugged.
The ShockDisplay curve 2 features an anodized aluminum housing with an IP67 protection rating. It is preferably mounted using a secure screw connection; magnetic mounting is also available as an option.
A secure connection between the data logger and the cargo is particularly important for accurate shock measurement. Cushioning materials between the logger and the equipment could distort the actual mechanical stress. For this reason, in practice, the devices are mounted as directly and securely as possible to the object being monitored.
The device is also designed for long-distance transport. With standard batteries, a measurement period of approximately one year is possible under typical conditions. The stored data is retained long-term, regardless of the condition of the main batteries.
Standard-Compliant Data for Demanding Transport Applications
Especially when it comes to high-quality industrial equipment, measurement data must be traceable and reliable.
The ShockDisplay curve 2 meets various relevant standards for this purpose. These include, among others:
- Shock evaluation according to DIN EN 15433-6
- Frequency analysis according to DIN EN 13011
- Use in accordance with IEEE C57.150-2012
This makes the device particularly suitable for the routine transport monitoring of energy equipment such as transformers, switchgear, and generators.
What are the practical benefits of the ShockDisplay curve 2?
The data logger’s value becomes particularly apparent after a transport is completed.
If no abnormal stresses occurred, data is available to document the transport process. This helps avoid unnecessary inspection and maintenance work, if any, and allows equipment to be processed further or put into operation more quickly.
If, on the other hand, a critical event is detected, a more targeted response is possible.
For example:
- affected components can be inspected,
- necessary tests can be prepared,
- appropriate replacement parts can be organized,
- or repair measures can be planned.
Recurring stresses can also be analyzed. If noticeable shock or tilt events occur regularly at specific points in a transport process, future operations can be specifically improved. This reduces the risk of damage, optimizes transport processes, and lowers costs in the long term. At the same time, efficiency increases, as unplanned repairs, time-consuming additional inspections, and transport-related downtime can be avoided. The objective documentation of the transport process also provides a solid foundation for quality assurance, complaint handling, and continuous improvement measures.
For example, a transformer application highlights these benefits: standards-compliant data recording, rapid insight into the condition of the cargo, more targeted responses to damage, and reduced costs through optimized processes.
Your Benefits at a Glance
- Three-dimensional detection of shock events
- Storage of the 500 largest shock events
- Detailed recording of shock curves
- Additional monitoring of tilt events
- Customizable recording and alarm thresholds
- Direct display of key measurement and status information
- Operation via display and function keys
- Detailed PC analysis via USB
- Rugged aluminum housing with IP67 protection rating
- Long service life
- Measurement and analysis compliant with standards
- Particularly suitable for high-value industrial and heavy-haul transport
Conclusion
The Monilog® ShockDisplay curve 2 goes far beyond simply recording a shock. It documents the intensity, direction, time, duration, and progression of mechanical stresses and combines this information with comprehensive tilt monitoring. This makes the shock recorder particularly well-suited for high-value and mechanically sensitive cargo such as transformers, generators, or switchgear.
Companies not only receive notification that a critical impact has occurred; the recorded data also helps them understand how the event unfolded and what further measures are advisable.
In this way, simple transport monitoring becomes a reliable foundation for damage analysis, quality assurance, and the continuous optimization of transport processes.
Frequently Asked Questions (FAQ):
What is the ShockDisplay curve 2?
The Monilog® ShockDisplay curve 2 is a rugged transport data logger designed to record and document shock and tilt events. It is used primarily for high-value and mechanically sensitive cargo.
What data does the ShockDisplay curve 2 record?
Among other things, the data logger records the magnitude, direction, time, and duration of shock events. Critical events are also stored as a signal waveform or shock curve. Additionally, tilt values can be documented.
How many shock events does the ShockDisplay curve 2 store?
According to the current Monilog® data sheet, the ShockDisplay curve 2 stores the 500 shock events with the highest amplitude.
Can the ShockDisplay curve 2 be operated directly on the device?
Yes. The data logger features a backlit display and four function keys. This allows various measurement and status information to be displayed directly and device settings to be adjusted.
For which types of cargo is the ShockDisplay curve 2 suitable?
The device is particularly suitable for high-value industrial plants and energy equipment. Typical applications include monitoring the transport of transformers, generators, and switchgear.
How is the recorded data analyzed?
The data can be transferred to a PC via a USB connection and analyzed graphically and in tabular form using the accompanying Monilog® software.
What is the difference between a single shock value and a shock curve?
A single shock value, for example, indicates the maximum acceleration of an event. A shock curve, on the other hand, plots the load over time. This allows for a more detailed analysis of an event.
Would you like to reliably monitor high-value cargo?
The Monilog® ShockDisplay curve 2 documents shock and tilt events during transport, storage, and operation, thereby providing a solid foundation for evaluating mechanical stresses.